intersciencefire

EN 60754-1 · EN 60754-2

Acidity of Gases from Cable Materials

Determines the degree of acidity of gases evolved during combustion of materials taken from electric cables by measuring pH and conductivity.

Test on gases evolved during combustion of materials from cables — Determination of halogen acid gas content (Part 1); Determination of acidity (by pH measurement) and conductivity (Part 2)

Tube furnace with gas capture and pH/conductivity measurement test equipment

Test overview

The International Electrotechnical Commission IEC 60754 Part 1 and Part 2 test is performed to determine the degree of acidity of gases evolved during the combustion of materials taken from electric cables by measuring the pH and conductivity.

Sample requirements

Sample dimensions, quantities, mounting, substrate and conditioning requirements for this test are confirmed with you before testing begins. Contact our technical team for the sample requirements for your product.

Equipment and outputs

Equipment used
Tube furnace with gas capture and pH/conductivity measurement
Reported measurements
Halogen acid gas content · pH · Conductivity

Related tests

Not certain whether this is the correct test for your product?

Send us a datasheet or a short description of your product and we will tell you exactly which tests apply, before any testing is booked.